RadioLabs - The Radio People - Home Technology Contact Us Visit our knowledge base Broadband Wireless
RadioLabs
Radio Products
Wireless Electronics Support
Meters and Multimeters Test Equipment and Instruments Power Computer Hardware Electronic
Bench-Top Multimeter
 

Bench-Top Multimeter
This is a highly accurate bench-top multimeter that offers true RMS, memory storage, and an easy to read LCD display.

 
Specifications
Model # BTM

DC Voltage

Range Resolution Accuracy
400mV 0.1mV 0.3% of rdg 35digits
4V 1mV 0.3% of rdg 2 digits
40V 10mV 0.3% of rdg 2 digits
400V 100mV 0.3% of rdg 2 digits
1000V 1V 0.3% of rdg 2 digits
Input Impedendance:10M Ohm <100pF

AC Voltage(True RMS,ac-coupled)

Range Resolution Accuracy

50Hz-60Hz

40Hz-1000Hz

4V 1mV 0.8% of rdg 5 digits 1.20% of rdg 10digits
40V 10mV 0.8% of rdg 2 digits 1.20% of rdg 10 digits
400V 100mV 0.8% of rdg  2digits 1.20% of rdg 10 digits
750V 1V 0.8% of rdg 5 digits 1.20% of rdg 15 digits
Inpendance:2M Ohm,Frequency Range: 40Hz to 1000Hz, Response: average,calibrated in rms of sine wave

DC Current

Range Resolution Accuracy Burden Voltage
4mA 1uA 0.8% of rdg 5 digits 600mV/mA
40mA 10uA 0.8% of rdg 5 digits 600mV/mA
400mA 100uA 0.8% of rdg 5 digits 600mV/mA
10A

(20A for 30 seconds)

10mA 1.50% of rdg 10 digits 900mV/A

AC Current

Range Resolution Accuracy Burden Voltage
4mA 1uA 1.50% of rdg 5 digits 600mV/mA
40mA 10uA 1.50% of rdg 5 digits 600mV/mA
400mA 100uA 1.50% of rdg 5digits 600mV/mA
10A 10mA 2.0% of rdg 10 digits 900mV/A
Frequency Range: 40Hz to 1000Hz, Response: Average in rms of since wave

Resistance

Range Resolution Accuracy
400 0.1 0.5% of rdg 5 digits
4K 1 0.5% of rdg 3 digits
40K 10 0.5% of rdg 3 digits
400K 100 0.5% of rdg 3 digits
4M 1k 0.5% of rdg 1 digits
40M 10K 0.5% of rdg 10 digits

Frequency

Range Resolution Accuracy
100 Hz 0.01Hz 0.1% of rdg 4digits
1KHz 1Hz 100mV rms for 1Hz to 20 KHz,500mV rms for 20Khz to 600KHz
100KHz 10Hz
600KHz 100Hz

Capacitance

Range Resolution Accuracy
4nF 1pF

2.0 % of rdg 40digits in relative mode

40nF 10pF

2.0 % of rdg 5digits in relative mode

400nF 100pF

2.0 % of rdg 5digits in relative mode

4uF 1nF

2.0 % of rdg 5digits at<20uF

40uF 10nF

5.0 % of rdg 5digits at>20uF

INPUT LIMITS

Function RED LEAD Connection Input Limits
400mV DC V Hz 250 V dc or rms ac
V dc & V ac V Hz 1000V dc, 750 ac(sine)
Hz V Hz 250 V dc or rms ac
Capacitance C 250V
Beep Diode V Hz 250V dc or rms ac
mA dc or mA ac mA 200mA dc or rms ac
V Hz 250V dc or rms ac
20A dc or 20A ac A 20A for 15 seconds Maximum
This is an exceptional bench-top multimeter that offers sophisticated performance at an unbeatable price.
 

Back to Bench-top Multimeter

Back to Multimeters

View all the Electronics

 
Share |

Join the RadioLabs mailing list :
Your information is kept private and only used for our newsletter.

subscribe unsubscribe

Product Spotlight
RadioLabs Product Spotlight
More Information
 
RadioLabs Specials
Great Deals at RadioLabs
Terms of Use     Privacy Policy     Site Map     Help     Contact     About
 
RadioLabs and RadioLabs.com are copyright. The contents of these webpages are RadioLabs International Inc., 2003-2010. All rights reserved. If you experience any problems with our site, please contact our webmaster
RadioLabs - The Radio People -